Consideraţii privind validarea şi asigurarea calităţii în punerea în funcţiune a IMRT şi VMAT

Show simple item record

dc.contributor.advisor RAILEAN, Serghei
dc.contributor.advisor CORDUN, Octavian
dc.contributor.author BEREGHICI, Vladislav
dc.date.accessioned 2025-02-28T10:39:58Z
dc.date.available 2025-02-28T10:39:58Z
dc.date.issued 2025
dc.identifier.citation BEREGHICI, Vladislav. Consideraţii privind validarea şi asigurarea calităţii în punerea în funcţiune a IMRT şi VMAT. Teză de master. Programul de studiu Inginerie Biomedicală. Conducător ştiinţific RAILEAN Serghei. Universitatea Tehnică a Moldovei. Chișinău, 2024. en_US
dc.identifier.uri https://repository.utm.md/handle/5014/30010
dc.description Fişierul ataşat conţine: Rezumat, Annotation, Cuprins, Introducere, Bibliografie. en_US
dc.description.abstract Scopul lucrării constă în efecturea procedurii de punere în funcțiune și asigurarea a calității în punerea în funcțiune a IMRT și VMAT. Obiectivele generale sunt: studiul literaturii pe tema tezei, însușirea principiului de funcționare a instalațiilor radioterapeutice și familiarizarea cu metodele dozimetrice de măsurare, dobândirea cunoștințelor necesare pentru realizarea testelor procedurii de punere în funcțiune a IMRT și VMAT. Domeniul de cercetare se bazează pe aspectele practice din radioterapie, incluzând dozimetria și asigurarea controlului calității, necesare procedurii de punere în funcțiune a MLC-ului. Originalitate științifică constă în realizarea procedurii de punere în funcțiune a colimatorului multilamelar, în vederea implementării tehnicilor avansate de tratament în radioterapie, ca radioterapia cu intensitate modulată și terapie arc volumetric modulată, în cadrul IMSP Institutul Oncologic. Teza cuprinde în sine introducere, trei capitole, concluzii și bibliografia. Capitolul 1 conține descrierea componentelor cheie ale echipamentului de radioterapie cu fascicul extern, alături de detaliile necesare despre colimatorul multilamelar, și de asemenea, principalele tehnici de iradiere din radioterapie. Capitolul 2 include fundamentele teoretice și practice ale procedurii de acceptare a colimatorului multilamelar, de asemenea, sunt incluse testele mecanice, evaluarea parametrilor lamelelor și verificările tehnicilor dinamice de radioterapie, pentru validarea funcționalității colimatorului multilamelar. Capitolul 3 descrie etapele de efectuarea a procedurii de punere în funcțiune, incluzând metoda de măsurarea spațiului dozimetric dintre lamele și determinarea factorului de transmisie. Totodată sunt prezentate descrierea testului „End-to-end” și justificarea rezultatelor obtinute. În concluzie, se menționeză, că scopul principal al proiectului a fost atins. A fost efectuat cu succes atât procedura de acceptare, cât și de punere în funcțiune a colimatorului multilamelar, iar rezultatele obținute au fost validate prin intermediul testului „End-to-end”, care au demonstrat încadrare în limitele nominale a parametrilor de interes. en_US
dc.description.abstract The purpose of the thesis is to perform the commissioning procedure and quality assurance for the implementation of IMRT and VMAT techniques. The general objectives are: studying the literature on the thesis topic, understanding the principles of operation of radiotherapy equipment, familiarizing with dosimetric measurement methods, and performing the commissioning procedure for IMRT and VMAT. The research field is based on the practical aspects of radiotherapy, including dosimetry and quality assurance, necessary for the commissioning procedure of the multileaf collimator. Scientific originality consists on the commissioning procedure of the multileaf collimator, aimed at implementing advanced radiotherapy treatment techniques, such as intensity-modulated radiotherapy and volumetric modulated arc therapy, within the IMSP Institute of Oncology. The thesis includes an introduction, three chapters, conclusions and the bibliography. Chapter one provides a description of the key components of external beam radiotherapy equipment, along with necessary details about the multileaf collimator, as well as the main irradiation techniques used in radiotherapy. The second chapter covers the theoretical and practical foundations of the multileaf collimator acceptance procedure, including mechanical tests, evaluation of leaf parameters, and verification of dynamic radiotherapy techniques to validate the functionality of the multileaf collimator. The third chapter utlines the steps for carrying out the commissioning procedure, including the method for measuring the dosimetric space between the leaves and determining the transmission factor. It also describes the "End-to-end" test and justifies the results. In conclusion, it is noted that the main objective of the project has been achieved. Both the acceptance and commissioning procedures for the multileaf collimator were successfully completed, and the results were validated through the "End-to-end" test, which demonstrated that the parameters of interest were within the nominal limits. en_US
dc.language.iso ro en_US
dc.publisher Universitatea Tehnică a Moldovei en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject accelerator liniar en_US
dc.subject colimator multilamelar en_US
dc.subject radioterapie en_US
dc.subject linear accelerator en_US
dc.subject multileaf collimator en_US
dc.subject commissioning en_US
dc.title Consideraţii privind validarea şi asigurarea calităţii în punerea în funcţiune a IMRT şi VMAT en_US
dc.title.alternative Considerations regarding validation and quality assurance in the commissioning of IMRT and VMAT en_US
dc.type Thesis en_US