IRTUM – Institutional Repository of the Technical University of Moldova

Ignition Method of Corona Discharge with Modulation of the Field in Ion Source of Ion Mobility spectrometer

Show simple item record

dc.contributor.author GROMOV, Evgeniy
dc.date.accessioned 2019-10-25T09:52:24Z
dc.date.available 2019-10-25T09:52:24Z
dc.date.issued 2011
dc.identifier.citation GROMOV, Evgeniy. Ignition Method of Corona Discharge with Modulation of the Field in Ion Source of Ion Mobility spectrometer. In: ICNBME-2011. International conference on Nanotechnologies and Biomedical Engineering. German-moldovan workshop on Novel Nanomaterials for Electronic, Photonic and Biomedical Applications: proc. of the intern. conf., July 7-8, 2011. Chişinău, 2011, pp. 231-233. ISBN 978-9975-66-239-0. en_US
dc.identifier.isbn 978-9975-66-239-0
dc.identifier.uri http://repository.utm.md/handle/5014/5275
dc.description.abstract The new method for the ignition of the corona discharge has been developed, which improves the stability of the ion mobility spectrometer and the resolution of the instrument. The system of forming a corona discharge without additional electrodes, which are used in a number of known structures for the pre-ionization, has been developed. This simplifies the design of the proposed source and an electronic control circuit. IMS technology is widely used in different civil and military fields for vapor-phase detection of explosive, narcotics, chemical warfare agents, biology molecules and so on. There are set of methods whose are used for the ionization of molecules under analysis. They are the following: radioactive ionization, ultraviolet photoionization, laser ionization, electric field ionization, coronaspray ionization, electrospray ionization, roentgen ionization, and surface ionization. All these methods has their own advantages and disadvantages. A comparing of ion mobility spectra of non-polar hydrocarbons for photoionization, corona discharge ionization and 63Ni ionization, had carried in. In our work we have investigated four types of IMS spectrometers whose use different sources for molecules under analysis ionization. They use radioactive ionization, ultraviolet photoionization, laser ionization, and roentgen ionization. The traditional explosives had investigated in experiments. In electricity, a corona discharge is an electrical discharge brought on by the ionization of a fluid surrounding a conductor, which occurs when the potential gradient (the strength of the electric field) exceeds a certain value, but conditions are insufficient to cause complete electrical breakdown or arcing. en_US
dc.language.iso en en_US
dc.publisher Technical University of Moldova en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject ion spectrometers en_US
dc.subject spectrometers en_US
dc.subject corona en_US
dc.subject electrodes en_US
dc.title Ignition Method of Corona Discharge with Modulation of the Field in Ion Source of Ion Mobility spectrometer en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account