IRTUM – Institutional Repository of the Technical University of Moldova

Using non gas analyzer method about diagnosing of leakage of the refrigerating agent from refrigerating system of the household refrigerator «NОRD» - dh -239

Show simple item record

dc.contributor.author GORIN, Alexander
dc.contributor.author DEMIN, Michael
dc.date.accessioned 2019-11-05T06:42:22Z
dc.date.available 2019-11-05T06:42:22Z
dc.date.issued 2012
dc.identifier.citation GORIN, Alexander, DEMIN, Michael. Using non gas analyzer method about diagnosing of leakage of the refrigerating agent from refrigerating system of the household refrigerator «NОRD» - DH -239. In: Modern technologies, in the food industry–2012: proc. of the intern. conf., November 1–3, 2012. Chişinău, 2012, vol. 1, pp. 88-92. ISBN 978-9975-80-645-9. en_US
dc.identifier.isbn 978-9975-80-645-9
dc.identifier.uri http://repository.utm.md/handle/5014/6038
dc.description.abstract In this work it is demonstrated the theoretical bases and results of experiments regarding distribution of temperature on a surface of the evaporator and in volume of the freezing chamber of the household DH-239 refrigerator (HR) working with isobutene. The values of temperature were received by means of computing algorithm of mathematical model [1] and defined experimentally, depending on a dose of filling are compared by isobutene of refrigerating system and ambient temperature. The action principle, the location of the sensor and settings of the device of automatic equipment signaling about leak of a coolant from the HR refrigerating system, are proved at various uptake of a temperature regulator, in the range of ambient temperature from 16 up to 43 degrees Celsius. en_US
dc.language.iso en en_US
dc.publisher Tehnica UTM en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject household refrigerator en_US
dc.subject evaporator en_US
dc.subject isobutene en_US
dc.subject mathematical model en_US
dc.subject ambient temperature en_US
dc.title Using non gas analyzer method about diagnosing of leakage of the refrigerating agent from refrigerating system of the household refrigerator «NОRD» - dh -239 en_US