IRTUM – Institutional Repository of the Technical University of Moldova

Accuracy Analysis of Measurements in Electrochemical Biosensing

Show simple item record

dc.contributor.author MAKIEWICZ, P.
dc.contributor.author MATIAS, D.
dc.contributor.author JASKUŁA, M.
dc.contributor.author BIEGUN, M.
dc.contributor.author PENKALA, K.
dc.contributor.author MIJOWSKA, E.
dc.contributor.author El FRAY, M.
dc.contributor.author PODOLSKI, J.
dc.date.accessioned 2020-05-18T10:45:48Z
dc.date.available 2020-05-18T10:45:48Z
dc.date.issued 2015
dc.identifier.citation MAKIEWICZ, P., MATIAS, D., JASKUŁA, M. et al. Accuracy Analysis of Measurements in Electrochemical Biosensing. In: ICNMBE: International conference on Nanotechnologies and Biomedical Engineering: proc. of the 3rd intern. conf., Sept. 23-26 : Program & Abstract Book , 2015. Chişinău, 2015, p. 95. en_US
dc.identifier.uri https://doi.org/10.1007/978-981-287-736-9_89
dc.identifier.uri http://repository.utm.md/handle/5014/8243
dc.description Access full text - https://doi.org/10.1007/978-981-287-736-9_89 en_US
dc.description.abstract In the paper the results of research on accuracy analysis of measurements in electrochemical biosensing are presented. The scope of performed tests includes EIS (Electrochemical Impedance Spectroscopy) and chronoamperometry, widely used for determination of glucose concentration. Measurement results obtained with two microcontroller systems, designed within a research project, and one reference platform (Autolab system, Metrohm, Netherlands) are compared and discussed. As a result, optimal design solutions may be chosen for microcontroller-based biomeasurement system. In glucosensing, promising results were obtained with the EIS technique in experiments performed using the Autolab system. en_US
dc.language.iso en en_US
dc.publisher Tehnica UTM en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject biosensing en_US
dc.subject electrochemical biosensing methods en_US
dc.subject accuracy analysis en_US
dc.subject impedance scanners en_US
dc.subject glucometry en_US
dc.title Accuracy Analysis of Measurements in Electrochemical Biosensing en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account