IRTUM – Institutional Repository of the Technical University of Moldova

Development of the High-resolution Scintillator Type Imager Using Si GRID structures

Show simple item record

dc.contributor.author TABATA, K.
dc.contributor.author OHTAKE, R.
dc.contributor.author NISHIZAWA, J.
dc.contributor.author KOIKE, A.
dc.contributor.author AOKI, T.
dc.date.accessioned 2020-05-31T09:32:21Z
dc.date.available 2020-05-31T09:32:21Z
dc.date.issued 2019
dc.identifier.citation TABATA, K., OHTAKE, R., NISHIZAWA, J. et al. Development of the High-resolution Scintillator Type Imager Using Si GRID structures. In: ICNMBE: International conference on Nanotechnologies and Biomedical Engineering: proc. of the 4rd intern. conf., Sept. 18-21 : Program & Abstract Book , 2019. Chişinău, 2019, p. 156. ISBN 978-9975-72-392-3. en_US
dc.identifier.isbn 978-9975-72-392-3
dc.identifier.uri https://doi.org/10.1007/978-3-030-31866-6_129
dc.identifier.uri http://repository.utm.md/handle/5014/8498
dc.description Access full text - https://doi.org/10.1007/978-3-030-31866-6_129 en_US
dc.description.abstract The scintillator type X-ray image detector is being developed in this paper. The spatial resolution of this detector is not so higher than direct conversion type x-ray image detector because of scattering of luminescence of scintillator in the detector. The diffusion of light emit of scintillator by X-ray irradiated was suppressed by processing the silicon substrate using microfabrication technology. These small hole patterns were machined in a silicon substrate, and the scintillator was filled in the silicon grid holes. These holes reflect the light emitted by the scintillator and suppresses diffusion. The scintillator can be optically separated by this device. And these structures are operated as one detector. The purpose of this study is to prove that the silicon grid structures improve the spatial resolution of the scintillator type detector. Therefore, we measured the spatial resolution of the scintillator using this Si grid structures. In this study, CsI:Tl was buried in grid holes by the melting method. The spatial resolution of the sample in which CsI:Tl was deposited into the inside of the grid structure was measured. From this result, the deposition of the scintillator in the Si grid structures using the melting method has led to an improvement in spatial resolution of the scintillator type X-ray image detector. en_US
dc.language.iso en en_US
dc.publisher Tehnica UTM en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject grid structures en_US
dc.subject spatial resolution en_US
dc.subject X-ray image detectors en_US
dc.title Development of the High-resolution Scintillator Type Imager Using Si GRID structures en_US
dc.type Article en_US