dc.contributor.advisor | STRATAN, Ion | |
dc.contributor.author | GORAŞ, Serghei | |
dc.date.accessioned | 2021-02-17T09:00:52Z | |
dc.date.available | 2021-02-17T09:00:52Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | GORAŞ, Serghei. Evaluarea influenței comutatoarelor de reglaj al tensiunii sub sarcină a transformatoarelor de putere asupra regimului de funcționare a rețelei electrice: tz. de master: Programul de studiu: Electroenergetica. Cond. şt. STRATAN ION. Universitatea Tehnică a Moldovei. Chişinău, 2020. | en_US |
dc.identifier.uri | http://repository.utm.md/handle/5014/13085 | |
dc.description | Fișierul atașat conține: Rezumat, Abstract, Cuprins, Introducere, Bibliografie. | en_US |
dc.description.abstract | Structura lucrării: lucrarea conține o introducere, patru capitole, concluzii, bibliografie din 4 titlu și 9 link-uri utilizate, 59 pagini, 39 figuri, 6 tabele. Scopul lucrării: determinarea influenței comutatorului de reglaj a tensiunii sub sarcină asupra rețelei electrice. Obiectivele generale: analiza influenței comutatorului de reglaj a tensiunii sub sarcină asupra rețelei electrice, determinarea plotului optim pentru minimizarea pierderilor de putere. Rezultate obținute: în urma studiului s-a demonstrat impactul comutatorului de reglaj a tensiunii sub sarcină asupra rețelei electrice, au fost obținute pierderile de putere activă și reactivă sumare în rețea și s-a demonstrat că pierderile depind total de plotul transformatorului. | en_US |
dc.description.abstract | Thesis structure: the paper contains an introduction, four chapters, conclusions, bibliography of 4 titles and 9 links used, 58 pages, 39 figures, 6 tables. The scope of the work: determining the influence of the on-load tap-changer on the mains. General objectives: analysis of the influence of the voltage control switch under load on the electrical network, determination of the optimal plot to minimize power losses Result obtained: the study demonstrated the impact of the on-load voltage control switch on the mains, the losses of active active and reactive power in the network were obtained and it was shown that the losses depend entirely on the transformer plot. | en_US |
dc.language.iso | ro | en_US |
dc.publisher | Universitatea Tehnică a Moldovei | en_US |
dc.rights | Attribution-NonCommercial-NoDerivs 3.0 United States | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
dc.subject | plot | en_US |
dc.subject | priză | en_US |
dc.subject | transformator | en_US |
dc.subject | socket | en_US |
dc.subject | transformer | en_US |
dc.subject | voltage switch | en_US |
dc.title | Evaluarea influenței comutatoarelor de reglaj al tensiunii sub sarcină a transformatoarelor de putere asupra regimului de funcționare a rețelei electrice | en_US |
dc.title.alternative | Evaluation of the influence of on-load voltage control switches of the power transformers on the operating mode of the electrical network | en_US |
dc.type | Thesis | en_US |