DSpace Repository

Influența unghiului de înclinare a tubului de conducere și a vitezei aerului asupra fluxului de semințe dozate de aparatele cu cilindru canelat

Show simple item record

dc.contributor.author GHEORGHIŢA, Andrei
dc.date.accessioned 2023-06-22T08:17:19Z
dc.date.available 2023-06-22T08:17:19Z
dc.date.issued 2020
dc.identifier.citation GHEORGHIŢA, Andrei. Influența unghiului de înclinare a tubului de conducere și a vitezei aerului asupra fluxului de semințe dozate de aparatele cu cilindru canelat. In: Ştiinţa Agricolă. 2020, nr. 2, pp. 85-90. ISSN 1857-0003, eISSN 2587-3202. en_US
dc.identifier.issn 1857-0003
dc.identifier.issn 2587-3202
dc.identifier.uri http://repository.utm.md/handle/5014/23228
dc.description.abstract În articol sunt prezentate rezultatele studiului influenței unghiului de înclinare a tubului de conducere și a vitezei aerului asupra fluxului de semințe dozate de aparate cu cilindru canelat, obținute la instalația experimentală asistată de calculator. Scopul cercetării a fost stabilirea valorilor optime ale unghiului de orientare a tubului de conducere și ale vitezei aerului la care se asigură o uniformitate de repartizare mai bună a semințelor de-a lungul rândului. Obiect al cercetării este tubul de conducere, care a fost instalat sub unghiul de înclinare ε = 0; 15; 30° față de axa verticală de scurgere a semințelor de pe clapeta mobilă. Regimurile de lucru ale instalației au fost: turațiile cilindrului canelat n=10; 20; 30; 40; 50; 60 min-1; viteza fluxului de aer Va=0; 2; 4; 4,5; 6; 8 m/s. Analiza rezultatelor obținute arată că unghiul de înclinare a tubului de conducere ε = 30° reduce coeficientul de variație a timpului dintre seminţe la 53,48 %. Această valoare este cu 24,35% mai mică față de cea caracteristică pentru sistemul standard de distribuție (77,83%). Factorul care influențează cel mai mult coeficientul de variație a timpului dintre semințe (41,36%) la sistemul de distribuție este viteza aerului, cu valoarea optimă de 8 m/s la valoarea 10 min-1 a turațiilor. en_US
dc.description.abstract The article presents study results of the influence of seed tube inclination angle and air velocity on the seeds flow dosed by devices with fluted roller. The results were obtained at the computer-assisted experimental installation. The research goal was to establish the optimal operating values of seed tube orientation angle and the air velocity at which a better uniformity distribution of seeds along the row is assured. The object of the research is seed tube, which was installed under the inclination angles ε = 0; 15; 30° to the vertical axis of seed discharge of the movable flap. The installation working regimes were: the fluted roller speed n = 10; 20; 30; 40; 50; 60 min-1; air flow velocity Va = 0, 2, 4, 4,5, 6, 8 m/s. Analysis of the obtained results shows that the seed tube inclination angle ε = 30° at the distribution system, decreases the time coefficient of variation between seeds to 53.48%. This value is 24.35% lower than the one that is characteristic for the standard distribution system 77.83%. The factor that most influence the time coefficient of variation between seeds (41.36%) at distribution system, is the air speed 8 m/s at the roller speed 10 min-1.
dc.language.iso ro en_US
dc.publisher Universitatea Agrară de Stat din Moldova en_US
dc.relation.ispartofseries Știința Agricolă;2020, N. 2
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject organ de incorporare a semințelor en_US
dc.subject parametri constructivi en_US
dc.subject sămânţă en_US
dc.subject semănători en_US
dc.subject sisteme de distribuție en_US
dc.subject design parameters en_US
dc.subject distribution systems en_US
dc.subject seed embedding device en_US
dc.subject seeds en_US
dc.title Influența unghiului de înclinare a tubului de conducere și a vitezei aerului asupra fluxului de semințe dozate de aparatele cu cilindru canelat en_US
dc.title.alternative Influence of seed tube inclination angle and air velocity on the seed flow dosed by devices with fluted rolle en_US
dc.type Article en_US