DSpace Repository

Design and Simulation of a Biocompatible Prosthesis Ti-15Mo-XTa Alloy: An Analysis of Mechanical Integrity Using Finite Element Modeling

Show simple item record

dc.contributor.author SAUD, A. Najah
dc.contributor.author MAJDI, Hasan Sh.
dc.contributor.author KOÇ, Erkan
dc.contributor.author MAAMORI, Mohammed Al
dc.date.accessioned 2023-11-06T11:28:15Z
dc.date.available 2023-11-06T11:28:15Z
dc.date.issued 2023
dc.identifier.citation SAUD, A. Najah, MAJDI, Hasan Sh., KOÇ, Erkan. Design and Simulation of a Biocompatible Prosthesis Ti-15Mo-XTa Alloy: An Analysis of Mechanical Integrity Using Finite Element Modeling. In: 6th International Conference on Nanotechnologies and Biomedical Engineering: proc. of ICNBME-2023, 20–23, 2023, Chisinau, vol. 1: Nanotechnologies and Nano-biomaterials for Applications in Medicine, 2023, p. 305-312. ISBN 978-3-031-42774-9. e-ISBN 978-3-031-42775-6. en_US
dc.identifier.isbn 978-3-031-42774-9
dc.identifier.isbn 978-3-031-42775-6
dc.identifier.uri https://doi.org/10.1007/978-3-031-42775-6_34
dc.identifier.uri http://repository.utm.md/handle/5014/24644
dc.description Acces full text - https://doi.org/10.1007/978-3-031-42775-6_34 en_US
dc.description.abstract The main focus of this work is the development and simulation of a prosthesis using a high entropy alloy known as Ti-15Mo-XTa. The selection of this alloy is based on its compatibility with the human body, which is a crucial factor when choosing materials for medical implants. Traditional metal implants can cause several problems for patients, including toxic reactions from the release of metal ions, wear and tear of joint replacements from movement, and structural failure from repetitive loading. To address these concerns, the present study creates a three-dimensional finite element model of the prosthesis using COMSOL software. The model includes both isotropic and anisotropic materials and is subjected to various mechanical loads based on experimental studies. The finite element method is used to analyze the distribution of stress and strain across adjacent elements of the prosthesis. By simulating the behavior of the prosthesis under different loading conditions, valuable insights into its performance and durability can be gained. To assess the static design, the prosthesis is tested using COMSOL simulation software and subjected to loading conditions of 70, 90 and 110 kg. The objective of this assessment is to determine the robustness and ability of the design to withstand real-world mechanical demands. By conducting these simulations and tests, the researchers hope to contribute to the development of improved prostheses that can offer better functionality, longevity and overall patient satisfaction. en_US
dc.language.iso en en_US
dc.publisher Springer Nature Switzerland en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject prosthesis en_US
dc.subject high entropy alloys en_US
dc.subject titanium alloys en_US
dc.subject femurs en_US
dc.subject finite element analysis en_US
dc.title Design and Simulation of a Biocompatible Prosthesis Ti-15Mo-XTa Alloy: An Analysis of Mechanical Integrity Using Finite Element Modeling en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

  • 2023
    6th International Conference on Nanotechnologies and Biomedical Engineering, September 20–23, 2023, Chisinau, Moldova

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Advanced Search

Browse

My Account