DSpace Repository

Statistical Distortion Detection of Interference Microscope Image

Show simple item record

dc.contributor.author SOKOL, Yevgen
dc.contributor.author SHCHAPOV, Pavlo
dc.contributor.author BERNADSKAYA, Tatyana
dc.contributor.author CHMYKHOVA, Oksana
dc.contributor.author KOLISNYK, Kostyantyn
dc.date.accessioned 2023-11-13T13:08:30Z
dc.date.available 2023-11-13T13:08:30Z
dc.date.issued 2023
dc.identifier.citation SOKOL, Yevgen, SHCHAPOV, Pavlo, BERNADSKAYA, Tatyana et al. Statistical Distortion Detection of Interference Microscope Image. In: 6th International Conference on Nanotechnologies and Biomedical Engineering: proc. of ICNBME-2023, 20–23, 2023, Chisinau, vol. 2: Biomedical Engineering and New Technologies for Diagnosis, Treatment, and Rehabilitation, 2023, p. 134-143. ISBN 978-3-031-42781-7. e-ISBN 978-3-031-42782-4. en_US
dc.identifier.isbn 978-3-031-42781-7
dc.identifier.isbn 978-3-031-42782-4
dc.identifier.uri https://doi.org/10.1007/978-3-031-42782-4_15
dc.identifier.uri http://repository.utm.md/handle/5014/24778
dc.description Acces full text - https://doi.org/10.1007/978-3-031-42782-4_15 en_US
dc.description.abstract The purpose of the article is reducing distortions of geometric characteristics which characterize the density uniformity of the erythrocytes quantity distribution on the plane of the microscope image due to the technical improvement of the optical scheme of the polychrome microscope, based on the use of the coherent source of light. For a comparative study of the operational properties of a semiconductor light source, two types of lasers were chosen: laser 1 is a light laser diode and laser 2 is a laser module with additional optical elements. The image plane was divided into 36 rectangular zones: 4 central, 12 intermediate and 20 edge. Counting of uniformity distributed erythrocytes number for each of the zones made it possible to statistically compare the distortions of the initial uniformity for lasers 1 and 2. The use of linear regression analysis with applying Fisher's F-statistics for evaluation of the regression statistical significance led to important conclusions. Statistical analysis showed that for lasers 1 and 2 there are different geometric curvatures of the image. Laser 2 has order of magnitude smaller edge effects for the aver-age density of erythrocytes quantity for each of the 36 zones created with a help of modified chamber equivalent to a Goryaev chamber. It is proved that the edge effects for laser 1 are statistically uniform over the entire perimeter of the image. As for the laser 2, its use does not provoke geometric curvatures of the image, including geometric models of edge effects. The presence of additional optical elements in the laser 2 solves the problem of technical improvement of the light source, ensuring the achievement of the purpose. en_US
dc.language.iso en en_US
dc.publisher Springer Nature Switzerland en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject interference microscope en_US
dc.subject erythrocytes shapes en_US
dc.subject linear regression analysis en_US
dc.subject microscope images en_US
dc.subject fisher statistics en_US
dc.title Statistical Distortion Detection of Interference Microscope Image en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

  • 2023
    6th International Conference on Nanotechnologies and Biomedical Engineering, September 20–23, 2023, Chisinau, Moldova

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Advanced Search

Browse

My Account