2011: Recent submissions

  • ABABII, I.; ARAMA, E. (Technical University of Moldova, 2011)
    The results of elaboration, construction and implementation of ultraviolet radiation detector with high sensibility are presented, which is used as portable device for measuring the intensity and dose. Photodetectors possess ...
  • SAULEA, Aurel; CHIHAI, Victoria (Technical University of Moldova, 2011)
    We conducted a double blinded prospective trial to evaluate the change peripheral excitability effect of millimeter waves (MW) under experimental conditions. Sixty healthy volunteers were exposed to active medical MW ...
  • ABABII, I.; DANILOV, L.; MANIUC, M.; ABABII, P.; DIACOVA, S. (Technical University of Moldova, 2011)
    Tympanoplasty is a delicate microsurgery, surgery repairing an anatomical lesion of the middle ear, caused by suppuration of chronic otitis. The main direction of the study is to determine the efficacy of tympanoplasty ...
  • NICA, Iurie; ZAVRAJNÎI, Serghei; GRITZCO, Andrei; TIRON, Iurie; ESHANU, Dumitru; MUSTEATZA, Vladimir; STALBE, Andrei (Technical University of Moldova, 2011)
    As is well known, on heating up the tumor over 43 – 440C the tumor cells dies, whereas healthy tissues cells remain alive up to 500C. We propose local overheating malignant morbid growth, with infrared radiation from a ...
  • ABABII, I.; DIACOVA, S.; MANIUC, M.; ABABII, P.; DANILOV, L. (Technical University of Moldova, 2011)
    Several hundred children in the first year of life were evaluated and treated for a variety of diseases. Seven sets of measures were used in the study: 1. Background characteristics; 2. Otological questionnaires; 3. ...
  • ASIMOV, M. M.; ASIMOV, R. M.; RUBINOV, A. N.; GISBRECHT, A. I. (Technical University of Moldova, 2011)
    The results in vivo investigation biophotonics of laser-induced photodissosiation of oxyhemoglobin in cutaneous blood vessels and its role in biomedical processes are presented. New method for determination an individual ...
  • DEKHTYAR, Yuri; LANCERE, Linda; POLYAKA, Nataliya; SUDNIKOVICH, Alexander; TYULKIN, Fyodor (Technical University of Moldova, 2011)
    Prosthetic poly (methyl methacrylate) is widely used for medical applications like lenses and eye prostheses. For prosthetic products biocompatibility is essential, different methods have been developed to control it by ...
  • ARORA, Silki; PARK, Sang Hoon; MAUSER, Jennifer; CHAKRABARTI, Debopam; SCHULTE, Alfons (Technical University of Moldova, 2011)
    The erythrocytic cycle of the malaria parasite Plasmodium falciparum is marked with structural, mechanical and biochemical modifications to the host red blood cell. The parasite degrades the hemoglobin of the host cell and ...
  • DASCALU, Dan (Technical University of Moldova, 2011)
    IMT-Bucharest coordinated the national project ―”NANOPROSPECT: Nanotechnologies in Romania, a prospective study” (October 2010 – May 2011), whose objective was to put forward strategic orientations and recommendations for ...
  • PĂSTRĂVANU, C.; POPOVICI, M. E.; CRETESCU, I. (Technical University of Moldova, 2011)
    Abstract – TiO2 is the most frequently employed photocatalyst in realising complete mineralization of organic pollutants in water treatment. Its large bandgap energy necessitates though UV excitation to induce charge ...
  • ANGELSKY, V.; ZENKOVA, C. Yu. (Technical University of Moldova, 2011)
    We present the results of computer simulation of spatial distribution of the Poynting vector and illustrate motion of nano and microparticles in spatially inhomogeneously polarized fields. The influence of phase relations ...
  • BAKERENKOV, Alexander (Technical University of Moldova, 2011)
    The Enhanced Low Dose Rate Sensitivity (ELDRS) in bipolar devices consists of in base current degradation of NPN and PNP transistors increase as the dose rate is decreased [1]. As a result of almost 20-year studying, the ...
  • VASILIEV, Valery (Technical University of Moldova, 2011)
    The new method for the calibration of the ion mobility spectrometer has been developed. This article describes the working principle, advantages and disadvantages of the calibration method operating in the mode of explosives ...
  • GROMOV, Evgeniy (Technical University of Moldova, 2011)
    The new method for the ignition of the corona discharge has been developed, which improves the stability of the ion mobility spectrometer and the resolution of the instrument. The system of forming a corona discharge without ...
  • ŢURCAN, Marina (Technical University of Moldova, 2011)
    It is examined the coherence properties between the Stokes and anti-Stokes fields and its application in Communication. It is proposed novel two-photon entangled sources which take into account the coherence and collective ...
  • SMYSLOV, V.; YAKUNIN, V.; BELOTSERKOVSKII, I. (Technical University of Moldova, 2011)
    The TPH-485-0,06 submersible level transducer of hydrostatic pressure is a general-purpose sensor for measuring the level of fresh water or other mildly corrosive liquids. The TPH-485-0,06 submersible level transducer can ...
  • PENIN, Alexandr; SIDORENKO, Anatoli (Technical University of Moldova, 2011)
    The base approach, giving a wide class of functions convenient for engineering practice for the formal description of I-V characteristics of the MOSFET transistors, is developed. The similarity of I-V characteristics of ...
  • DMITROGLO, L.; UNTILA, D.; CHETRUSH, P.; EVTODIEV, I.; CARAMAN, Iu.; LAZAR, G.; NEDEFF, V. (Technical University of Moldova, 2011)
    In the paper, optical and photoelectrical properties of GaSe and InSe single crystal films of 10-5÷10-7 m submicron thickness and of semiconductor-native oxide structures obtained by annealing at (450÷700)°C in a normal ...
  • IASENIUC, O.; ANDRIESH, A.; ACHIMOVA, E.; ABASHKIN, V. (Technical University of Moldova, 2011)
    An elaboration the holographic fiber-optic electronic speckle pattern interferometer (ESPI) which can will be apply for measurement of the optical constants is described. This interferometer with CCD Smart Camera can be ...
  • MESHALKIN, A.; ANDRIES, A.; ACHIMOVA, E.; BETS, L.; ANDRIES, I.; DRAHNEA, S. (Technical University of Moldova, 2011)
    This paper deals with the interferometric thickness measurements of spin-coated thin polymer films. Spin coating is currently the predominant technique employed to produce uniform thin films of polymers in sub-micrometer ...

Search DSpace


Advanced Search

Browse

My Account