DSpace Repository

FEM-based Analysis on the Operation of Three-Phase Induction Motor connected to Six-Phase Supply System. Part 2 – Study on fault-tolerance capability

Show simple item record

dc.contributor.author LIVADARU, Leonard
dc.contributor.author BOBU, Alexandra
dc.contributor.author MUNTEANU, Adrian
dc.contributor.author VÎRLAN, Bogdan
dc.contributor.author SIMION, Alecsandru
dc.date.accessioned 2019-11-19T12:49:52Z
dc.date.available 2019-11-19T12:49:52Z
dc.date.issued 2017
dc.identifier.citation LIVADARU, Leonard, BOBU, Alexandra, MUNTEANU, Adrian et al. FEM-based Analysis on the Operation of Three-Phase Induction Motor connected to Six-Phase Supply System. Part 2 – Study on fault-tolerance capability [Resursă electronică]. In: SIELMEN 2017: Proceedings of the 11-th international conference on electromechanical and power systems, 11-13 octombrie, 2017. Chișinău, 2017, pp. 133-138. ISBN 978-1-5386-1846-2. en_US
dc.identifier.isbn 978-1-5386-1846-2
dc.identifier.uri http://repository.utm.md/handle/5014/7028
dc.description Abstract & References en_US
dc.description.abstract Based on the fact that the three-phase induction machine proves higher performance under six-phase supply, which was demonstrated in Part 1 of the paper, this work investigates the fault-tolerance capability of the six-phase structure with asymmetrical configuration (30° phase shifting both for space and time conditions). It is taken into discussion the cut-off of one, two and three phases respectively. The study is carried through FEM simulations under steady-state and transient conditions. en_US
dc.language.iso en en_US
dc.publisher Institute of Electrical and Electronics Engineers en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject three-phase induction motors en_US
dc.subject motors en_US
dc.subject supply systems en_US
dc.subject fault-tolerance en_US
dc.title FEM-based Analysis on the Operation of Three-Phase Induction Motor connected to Six-Phase Supply System. Part 2 – Study on fault-tolerance capability en_US
dc.type Article en_US