DSpace Repository

Considerations On Radiated Emission Measurements for a Laptop in a Semi-Anechoic Chamber

Show simple item record

dc.contributor.author DINA, Livia-Andreea
dc.contributor.author NICOLAE, Petre-Marian
dc.contributor.author SMĂRĂNDESCU, Ionuț Daniel
dc.contributor.author VOICU, Viorica
dc.date.accessioned 2019-11-20T11:03:38Z
dc.date.available 2019-11-20T11:03:38Z
dc.date.issued 2017
dc.identifier.citation DINA, Livia-Andreea, NICOLAE, Petre-Marian, SMĂRĂNDESCU, Ionuț Daniel et al. Considerations On Radiated Emission Measurements for a Laptop in a Semi-Anechoic Chamber [Resursă electronică]. In: SIELMEN 2017: Proceedings of the 11-th international conference on electromechanical and power systems, 11-13 octombrie, 2017. Chișinău, 2017, pp. 215-220. ISBN 978-1-5386-1846-2. en_US
dc.identifier.isbn 978-1-5386-1846-2
dc.identifier.uri http://repository.utm.md/handle/5014/7043
dc.description Abstract & References en_US
dc.description.abstract This paper presents some aspects on measurements of radiated emission from a Laptop. The used Standards are presented and discussed. The measurements were carried out in a Semi-Anechoic Chamber (SAC) in accordance with EN 55022 (CISPR 22) Standard. The test arrangement was in accordance with IEC 61000-4-3 Standard and the following equipment was included: reception antenna, signal generator and emission antenna. The measurements were made at a distance of 3 meters, according to the generic Standard IEC 61000-6-3. The radiated electromagnetic interference (EMI) was assessed in the frequency domain, for the frequency range of 30 MHz – 1 GHz, in compliance with CISPR 22 Standard. The test was performed to verify if the equipment under test (EUT) is operating according to the radiated emission limits imposed by the product Standard of the class in which the equipment is framed. The results were in satisfactory agreement with the limits imposed by CISPR 22 Standard. en_US
dc.language.iso en en_US
dc.publisher Institute of Electrical and Electronics Engineers en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject electromagnetic interference en_US
dc.subject radiated emission measurements en_US
dc.subject semi-anechoic chambers en_US
dc.subject electromagnetic compatibility en_US
dc.title Considerations On Radiated Emission Measurements for a Laptop in a Semi-Anechoic Chamber en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

  • 2017
    11-13 Oct. 2017

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Advanced Search

Browse

My Account