DSpace Repository

Methods for the Self Calibration of Ion Mobility Spectrometer

Show simple item record

dc.contributor.author VASILYEV, V.
dc.contributor.author PERSHENKOV, V.
dc.contributor.author SAMOTAEV, N.
dc.contributor.author BELYAKOV, V.
dc.contributor.author GOLOVIN, A.
dc.contributor.author MALKIN, E.
dc.contributor.author GROMOV, E.
dc.contributor.author IVANOV, I.
dc.contributor.author SHALTAEVA, Y.
dc.contributor.author LIPATOV, D.
dc.date.accessioned 2020-05-20T06:58:17Z
dc.date.available 2020-05-20T06:58:17Z
dc.date.issued 2015
dc.identifier.citation VASILYEV, V., PERSHENKOV, V., SAMOTAEV, N. et al. Methods for the Self Calibration of Ion Mobility Spectrometer. In: ICNMBE: International conference on Nanotechnologies and Biomedical Engineering: proc. of the 3rd intern. conf., Sept. 23-26 : Program & Abstract Book , 2015. Chişinău, 2015, p. 124. en_US
dc.identifier.uri https://doi.org/10.1007/978-981-287-736-9_130
dc.identifier.uri http://repository.utm.md/handle/5014/8296
dc.description Access full text - https://doi.org/10.1007/978-981-287-736-9_130 en_US
dc.description.abstract In transport systems like airports, subway or railway stations widely used ion mobility spectrometers for hazardous toxic gases or explosives traces detection. At the present time ion mobility spectrometers use ionization sources based on the corona discharge. These sources of ionization require frequent calibration, especially if the device is used in the portable embodiment where rapid changes in ambient atmosphere are possible. Error false positives in such systems are critical – the evacuation of passengers transport terminal and emergency calls. To improve situation with false errors we develop system for the self calibration of ion mobility spectrometer based on combination of explosives vapors of and products released during the corona discharge combustion. Designed calibration system is based on corona discharge for ion mobility spectrometry. The control system is integrated into the overall spectrometer structure. en_US
dc.language.iso en en_US
dc.publisher Tehnica UTM en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject ion mobility spectrometry en_US
dc.subject explosives en_US
dc.subject calibration en_US
dc.title Methods for the Self Calibration of Ion Mobility Spectrometer en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Advanced Search

Browse

My Account