DSpace Repository

Portable Campimeter to Evaluate Visual Field Modifications of Subjects with Low Vision State

Show simple item record

dc.contributor.author BARITZ, M. I.
dc.contributor.author APOSTOAIE, M. G.
dc.contributor.author LAZAR, A. M.
dc.date.accessioned 2020-05-23T14:43:50Z
dc.date.available 2020-05-23T14:43:50Z
dc.date.issued 2019
dc.identifier.citation BARITZ, M. I., APOSTOAIE, M. G., LAZAR, A. M. Portable Campimeter to Evaluate Visual Field Modifications of Subjects with Low Vision State. In: ICNMBE: International conference on Nanotechnologies and Biomedical Engineering: proc. of the 4rd intern. conf., Sept. 18-21 : Program & Abstract Book , 2019. Chişinău, 2019, p. 118. ISBN 978-9975-72-392-3. en_US
dc.identifier.isbn 978-9975-72-392-3
dc.identifier.uri https://doi.org/10.1007/978-3-030-31866-6_141
dc.identifier.uri http://repository.utm.md/handle/5014/8347
dc.description Access full text - https://doi.org/10.1007/978-3-030-31866-6_141 en_US
dc.description.abstract The low vision state that can be installed at the visual function level causes a change in a series of important visual system parameters, as well as a decrease in the quality of life of human subjects. Mostly, lowering the visual function level should be evaluated periodically in any kind of condition (at home, medical clinic or screening center) and in all cases the investigator optometrist should identify the situations in which subjects develop visual field limitations. These visual field limitations may indicate the onset of a wide range of ocular pathologies, which, if detected early, can control procedures of management evolution or even improve with various visual aids. In the first part of the paper are presented some general aspects regarding the field of vision and also its parameters to the human visual system. The second part describes the construction of a visual field assessment system based on the primary requirement of being portable and easy to use device. In the final part of the paper are presented the results obtained using this visual field evaluation device and the way it can be programmed for several types of evaluations. en_US
dc.language.iso en en_US
dc.publisher Tehnica UTM en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject visual fields en_US
dc.subject arduino boards en_US
dc.subject device low vision en_US
dc.title Portable Campimeter to Evaluate Visual Field Modifications of Subjects with Low Vision State en_US