IRTUM – Institutional Repository of the Technical University of Moldova

Evaluarea influenței comutatoarelor de reglaj al tensiunii sub sarcină a transformatoarelor de putere asupra regimului de funcționare a rețelei electrice

Show simple item record

dc.contributor.advisor STRATAN, Ion
dc.contributor.author GORAŞ, Serghei
dc.date.accessioned 2021-02-17T09:00:52Z
dc.date.available 2021-02-17T09:00:52Z
dc.date.issued 2020
dc.identifier.citation GORAŞ, Serghei. Evaluarea influenței comutatoarelor de reglaj al tensiunii sub sarcină a transformatoarelor de putere asupra regimului de funcționare a rețelei electrice: tz. de master: Programul de studiu: Electroenergetica. Cond. şt. STRATAN ION. Universitatea Tehnică a Moldovei. Chişinău, 2020. en_US
dc.identifier.uri http://repository.utm.md/handle/5014/13085
dc.description Fișierul atașat conține: Rezumat, Abstract, Cuprins, Introducere, Bibliografie. en_US
dc.description.abstract Structura lucrării: lucrarea conține o introducere, patru capitole, concluzii, bibliografie din 4 titlu și 9 link-uri utilizate, 59 pagini, 39 figuri, 6 tabele. Scopul lucrării: determinarea influenței comutatorului de reglaj a tensiunii sub sarcină asupra rețelei electrice. Obiectivele generale: analiza influenței comutatorului de reglaj a tensiunii sub sarcină asupra rețelei electrice, determinarea plotului optim pentru minimizarea pierderilor de putere. Rezultate obținute: în urma studiului s-a demonstrat impactul comutatorului de reglaj a tensiunii sub sarcină asupra rețelei electrice, au fost obținute pierderile de putere activă și reactivă sumare în rețea și s-a demonstrat că pierderile depind total de plotul transformatorului. en_US
dc.description.abstract Thesis structure: the paper contains an introduction, four chapters, conclusions, bibliography of 4 titles and 9 links used, 58 pages, 39 figures, 6 tables. The scope of the work: determining the influence of the on-load tap-changer on the mains. General objectives: analysis of the influence of the voltage control switch under load on the electrical network, determination of the optimal plot to minimize power losses Result obtained: the study demonstrated the impact of the on-load voltage control switch on the mains, the losses of active active and reactive power in the network were obtained and it was shown that the losses depend entirely on the transformer plot. en_US
dc.language.iso ro en_US
dc.publisher Universitatea Tehnică a Moldovei en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject plot en_US
dc.subject priză en_US
dc.subject transformator en_US
dc.subject socket en_US
dc.subject transformer en_US
dc.subject voltage switch en_US
dc.title Evaluarea influenței comutatoarelor de reglaj al tensiunii sub sarcină a transformatoarelor de putere asupra regimului de funcționare a rețelei electrice en_US
dc.title.alternative Evaluation of the influence of on-load voltage control switches of the power transformers on the operating mode of the electrical network en_US
dc.type Thesis en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States

Search DSpace


Browse

My Account