dc.identifier.citation | GUŢU, A., CARTOFEANU, V., GUŢU–CHETRUŞCA, C. Heat pumps utilization in the pasteurization installation. In: MTFI – 2014. Modern technologies, in the food industry–2014: proc. of the intern. conf., October 16–18, 2014. Chişinău, 2014, pp. 56-60. ISBN 978-9975-80-840-8. | en_US |
dc.identifier.isbn | 978-9975-80-840-8 | |
dc.identifier.uri | http://repository.utm.md/handle/5014/7067 | |
dc.description.abstract | The article shows a comparative analysis of two schemes of heat and cold supply of the pasteurization installation: the traditional scheme of heat delivery from the Power Plant and cold delivery from the refrigerator, and the supply scheme of both types from the double use heat pump. It is proved that in the supply scheme from the Heat Pump the total consumption of primary energy form external sources is over 1.5 times less than in the traditional scheme. | en_US |