IRTUM – Institutional Repository of the Technical University of Moldova

The Influence of the Treatment Mode of the Neutral in the 6-35 kV Networks on the Displacement Voltage in the Quasi-Stationary Regime

Show simple item record

dc.contributor.author DOBREA, Ina
dc.date.accessioned 2023-11-24T09:31:16Z
dc.date.available 2023-11-24T09:31:16Z
dc.date.issued 2019
dc.identifier.citation DOBREA, Ina. The Influence of the Treatment Mode of the Neutral in the 6-35 kV Networks on the Displacement Voltage in the Quasi-Stationary Regime. In: Annals of the University of Craiova. Electrical Engineering series. 2019, nr. 43, iss 1, pp. 128-133. ISSN 1842-4805. en_US
dc.identifier.issn 1842-4805
dc.identifier.uri http://repository.utm.md/handle/5014/24997
dc.description.abstract In the work are analyzed the quasi-voltage surges in the 6-35 kV networks with the neutral treatment by the electric arc compensation coil, mixed - by the compensation coil in association with the resistor, through the resistor. It determines the displacement voltage of the neutral. It is analyzed the influence of the degree of asymmetry on the displacement voltage of the neutral. There are presented the ways of connecting the neutral treatment devices: the electric arc compensation coil, the low voltage and medium voltage resistors, the low value resistor and the high value resistor. It is shown that the introduction of a resistor in neutral causes the active component to appear in the grounding current instead of the defect. This fact plays an important role in reducing the overvoltages, making selective current protections and increasing the reliability of the operation of the electrical installations. The selection of the optimum neutral grounding method is made for a long period of time, it involves a large volume of investments and a very careful technical foundation, so that the chosen solution is as best as possible for the network considered. For each grounding method, this article presents brief description and calculation of the neutral displacement voltage. en_US
dc.language.iso en en_US
dc.publisher University of Craiova en_US
dc.rights Attribution-NonCommercial-NoDerivs 3.0 United States *
dc.rights.uri http://creativecommons.org/licenses/by-nc-nd/3.0/us/ *
dc.subject supratensiuni en_US
dc.subject bobine de compensare en_US
dc.subject rezistoare de legare la pământ en_US
dc.subject rezistoare de valoare mică en_US
dc.subject rezistoare de valoare mare en_US
dc.subject transformatoare pentru crearea neutrului en_US
dc.subject neutru izolat en_US
dc.subject neutru compensat en_US
dc.subject curent de punere la pământ en_US
dc.subject deplasarea neutrului en_US
dc.subject overvoltages en_US
dc.subject compensation coil en_US
dc.subject neutral grounding resistors en_US
dc.subject low resistance grounding en_US
dc.subject high resistance grounding en_US
dc.subject earthing transformer en_US
dc.subject isolated neutral en_US
dc.subject compensated neutral en_US
dc.subject earth power current en_US
dc.subject neutral voltage displacement en_US
dc.title The Influence of the Treatment Mode of the Neutral in the 6-35 kV Networks on the Displacement Voltage in the Quasi-Stationary Regime en_US
dc.type Article en_US


Files in this item

The following license files are associated with this item:

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 United States Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 United States